Miami-Dade Building Recertification  ·  Broward Building Safety Inspection Program (BSIP)
Hablamos español  ·  (786) 505-5119
Miami-Dade & BrowardHow it worksServicesTeamProjectsFAQFree EvaluationEspañol
MIAMI-DADE: 40 / 30-YEAR RECERT
BROWARD: BSIP (25+ YRS)

Building recertification, handled end to end.

A field inspection team led by our Engineer of Record, Emilio Castro, P.E. Thorough assessments, drone aerial documentation, and only the repairs your building genuinely needs.

Missed deadlines and unresolved structural or electrical issues lead to fines, violations, and costly delays. We manage the entire process in Miami-Dade and Broward: inspection, reports, municipal filing, repair coordination, and final approval.

Get My Free Evaluation Report Urgent notice? Call (786) 505-5119
Watch: how recertification works2 minutes, from the county's letter to your certificate
35+
Years of recertification experience.
Engineer of Record since 1989.
Hundreds
Of buildings certified since 1989: condos, hotels, commercial, churches, industrial
#41592
Florida P.E. License, Emilio Castro, Engineer of Record
48h
Free building evaluation delivered within 48 hours
2
Counties: Miami-Dade & Broward · Se habla español
TWO COUNTIES, TWO SETS OF RULES

Know which program applies to your building.

The requirements are similar but not identical. We handle both, and we file with the right department, on the right form, the first time.

Miami-Dade County

BUILDING RECERTIFICATION · MIAMI-DADE CODE §8-11(f)
  • Buildings 30 years or older (25 years within 3 miles of the coast), commonly still called the "40-year recertification".
  • Structural and electrical inspection, plus infrared thermography (thermoscan) and parking lot illumination study.
  • 90 days from notice to submit sealed reports; repairs typically within 150–180 days.
  • Recurring every 10 years after the first certification.
Includes City of Miami, Miami Beach, Doral, Hialeah, Coral Gables, North Miami Beach and all municipalities in the county.

Broward County

BUILDING SAFETY INSPECTION PROGRAM (BSIP) · BORA POLICY #05-05
  • Buildings 25 years or older, then every 10 years. Buildings under 3,500 sq ft are exempt.
  • Structural and electrical inspection by a Florida-registered engineer or architect.
  • Thermography and parking lot illumination are generally not required in Broward, so you shouldn't pay for them.
  • 90 days from notice to submit; 180 days to complete required repairs.
Includes Fort Lauderdale, Hollywood, Miramar, Pembroke Pines, Tamarac, Sunrise and all Broward municipalities.
HOW IT WORKS

From the county's letter to your certificate.

1

Notice and free evaluation

You receive a letter (or find your building on the county's list). Send us the address and within 48 hours you'll know your deadline, any open violations, and what to expect.

DAY 0
2

Inspection

Our field team, led by the Engineer of Record, inspects structure and electrical systems, runs the thermoscan and illumination study where required, and captures drone aerial documentation of roofs and façades.

WITHIN 2 WEEKS
3

Sealed reports and filing

Emilio Castro, P.E. seals the structural and electrical reports. We file them with the building department and act as your representative before the county or city. Typically filed within 45 days of signing, half the county's 90-day deadline, so there is time left for repairs if needed.

WITHIN 45 DAYS
4

Repairs and certification

If deficiencies are found, we scope only what's required, coordinate contractors and permits, and manage the reinspection through final certification.

WITHIN 180 DAYS
WHAT'S INCLUDED

Everything the county asks for, plus the things it doesn't tell you about.

STR

Structural Inspection and Report

Foundations, load-bearing walls, beams, columns, slabs, balconies and roof structure. Cracks, spalling, corroded rebar and moisture damage are documented with photos and a sealed deficiency report.

ELE

Electrical Inspection and Report

Service equipment, panels, feeders, grounding, emergency lighting and exit signs, evaluated against county requirements and documented in a sealed report.

AIR

Drone Aerial Documentation

High-resolution aerial photos and video of roofs, parapets, façades and areas that are unsafe or impossible to reach on foot. Included in every inspection, with a clear before/after record for your board and your insurer.

IR

Infrared Thermography

Required in Miami-Dade for electrical services of 400 A and above: detects overheating connections invisible to a visual inspection. We sample per county guidance rather than charging you for every panel.

LUX

Parking Lot Illumination Study

Light-level measurements and report for parking areas (Miami-Dade Chapter 8C). Included in our Miami-Dade recertification, not sold as an add-on.

REP

Repair Coordination and Owner Representation

Repair drawings when required, contractor coordination, permits, extension requests and reinspections. We represent you before the building department through the final letter.

REAL PROJECT, MIAMI BEACH

A $295,000 estimate that turned out to cost under $10,000.

A building owner near Miami Beach came to us after another firm quoted a six-figure repair scope. Our Engineer of Record inspected the property and recommended only what the building genuinely needed.

ANOTHER FIRM QUOTED
$295,000
Broad repair scope, presented before a detailed engineering inspection.
ACTUAL REQUIRED SCOPE
$5K to $10K
Verified by our Engineer of Record after a thorough structural and electrical inspection.
An accurate scope protects you from inflated contractor bids and gives you control over your repair costs. Not every building has a story like this one, but every building deserves a scope based on what an engineer actually found.
THE TEAM BEHIND THE SEAL

Led by our Engineer of Record. Backed by a full engineering team.

Every inspection is performed and sealed by Emilio Castro, P.E., supported by the engineers and architects of E.C. and Associates, Inc. Recertify Miami coordinates the project from first call to final certificate, so you deal with one point of contact and never have to chase anyone.

Emilio D. Castro, P.E.
Engineer of Record, E.C. and Associates, Inc.
Certifying South Florida buildings since 1989. Performs and seals every structural and electrical inspection personally, and directs the field team on every project.
FL P.E. #41592 · C.A. #06576
STR

Structural Engineering

Engineers evaluate foundations, columns, beams, slabs, balconies and roof structure, and prepare the sealed structural report and repair drawings when required.

ELE

Electrical Engineering

Electrical engineers inspect service equipment, panels, feeders, grounding and emergency systems, and run the thermoscan where the county requires it.

ARC

Architecture

Two architects document the building envelope and façades, coordinate unit access, and prepare the deficiency reports and drawings.

AIR

Drone Documentation

FAA Part 107 certified aerial photo and video of roofs, parapets and façades on every inspection.

PM

Project Coordination

Recertify Miami manages scheduling, municipal filings, contractors, extensions and the county, in English or Spanish, from the first call to the final letter.

ABOUT RECERTIFY MIAMI

Building Recertification and Compliance Consulting

Recertify Miami helps building owners, property managers and homeowners' associations navigate building recertification in Miami-Dade and the Building Safety Inspection Program in Broward. We coordinate the whole process, from inspection and sealed reports to municipal filing, repairs and final certification, so you deal with one person, not five.

Engineering is performed and sealed by our Engineer of Record, Emilio D. Castro, P.E. (FL #41592), who has certified South Florida buildings since 1989. Our field team documents every inspection with photos, thermography where required, and drone aerials of roofs and façades.

FREE BUILDING EVALUATION

Find out where your building stands in 48 hours.

Enter your property address and our team, working with our Engineer of Record, will confirm which program applies (Miami-Dade or Broward), your deadline, any violations on record, and what to expect. No cost, no obligation. Small buildings (under 2,500 sq ft) start at $3,950, all-inclusive.

Condominiums & HOAsHotels & hostelsApartment buildingsOffice & retailChurchesWarehouses & industrialMobile home park buildings
You'll receive your building's evaluation within 48 hours. Hablamos español.
★★★★★
Google reviews from completed projects
DL
Domingo Llerandi
General Manager, Viajero Hostel
★★★★★

"Recertify Miami made our recertification process simple and stress-free. Their team was responsive, professional, and delivered everything on time."

✓ VERIFIED CLIENT
OL
Oscar Linares
General Manager, Best Western On The Bay
★★★★★

"Knowledgeable, organized, and easy to work with. They guided us through the entire process and exceeded our expectations."

✓ VERIFIED CLIENT
KL
Kenny Lipschutz
CEO, Blue Suede Group
★★★★★

"Outstanding service and exceptional expertise. A reliable partner we trust."

✓ VERIFIED CLIENT
RECENT PROJECTS

A record you can look up.

Real buildings, real case numbers, real photos, including the drone aerials we use to document roofs and façades before and after repairs.

CERTIFIED

Best Western Hotel

1855 79th Street Causeway, North Bay Village

Shoring and repair drawings, full structural and electrical repairs, all violations resolved, certified in under five months, on time and below budget.

CERTIFIED

The Stiles Hotel

1120 Collins Avenue, Miami Beach

Repair drawings, structural and electrical work, and certification within four months, clearing all "unsafe structure" violations.

CERTIFIED

The Alamac Apartments

1300 Collins Avenue, Miami Beach

Structural repairs at height using swing stages; certified well below the cost proposed by competing bidders.

IN PROGRESS

Esprit Condominium II

9648 SW 138th Avenue, Miami

108 units across 9 buildings, 40-year recertification. Full exterior and interior inspection program in progress.

IN PROGRESS

Doral Isles Condominium

6350 NW 110th Avenue, Doral

30-year recertification, 3 buildings. Inspections complete; deficiency reports in preparation.

REPORTS DELIVERED

Hotel Astor

956 Washington Avenue, Miami Beach

Structural and electrical deficiency reports submitted to the City of Miami Beach; repair scope defined to close the open unsafe-structure case.

FREQUENTLY ASKED

Common questions, straight answers.

Who is responsible for scheduling the inspection, the owner or the county? +
The owner. The county sends the notice, but it doesn't schedule anything, and not receiving the letter is not a defense. If your building is on the published list, the clock is running.
What happens if I miss the deadline? +
Violations and daily fines, an enforcement case, and in serious cases an unsafe-structure order. Acting early is always cheaper than acting after a case is opened, and we can request extensions when a case already exists.
Is it "40-year" or "30-year"? What changed after Surfside? +
After Senate Bill 4D, Miami-Dade moved the first inspection to 30 years (25 within 3 miles of the coast) and Broward's BSIP starts at 25 years. People still say "40-year recertification". We'll confirm exactly which rule applies to your address in the free evaluation.
How much does it cost? +
Small buildings (under 2,500 sq ft) start at $3,950, all-inclusive. Larger properties depend on square footage, number of buildings, electrical service size and condition. We quote a fixed fee after the free evaluation, with thermoscan and illumination included where required and never as surprise add-ons.
Do you work with condo boards and property managers? +
Most of our projects come through property managers and HOA boards. We present to the board, coordinate unit access, and give you one point of contact for the whole process.
Why do you fly drones? +
Roofs, parapets, cornices and upper façades are where deterioration hides and where it's dangerous to inspect on foot. Aerial photos and video give the engineer a complete view, and give your board a clear before/after record.
Is thermography (thermoscan) required? +
In Miami-Dade, yes, for electrical services of 400 amps and above. It's part of the electrical recertification. In Broward it is generally not required, and we won't charge you for it there.
Does the Milestone Inspection / SIRS apply to a 2-story building? +
No. Milestone Inspections and SIRS apply to condos and co-ops three stories and higher. Smaller buildings still fall under county recertification depending on age. See our Milestone Inspection & SIRS page.
What if deficiencies are found? +
A deficiency report is not a condemnation. It's a repair list. We scope only what the county actually requires, help you get competitive contractor bids, and manage permits and reinspection.
¿Hablan español? +
Sí. Todo el proceso (evaluación, propuesta, inspección y seguimiento) puede hacerse completamente en español.

Last reviewed: September 2026 · Technical content reviewed by Emilio D. Castro, P.E. (FL #41592), Engineer of Record